Attention!

The limit for an input event is one per line!

Only variable conditions can be combined in one line. If you need input combinations you have to do this via variables.



This project consists of three shows and is triggered with three switches.


The first show should start, if switch 1 and 3 are closed and switch 2 is open.

The seconds show should start, if switch 1 and 2 are closed and switch 3 is open.

The third show should start, if switch 1 is open and switch 2 and 3 are closed.


The content of the Control.ini file looks like this:



!i1c!vmc1=1#

!i1o!vmc1=0#

!i2c!vmc2=1#

!i2o!vmc2=0#

!i3c!vmc3=1#

!i3o!vmc3=0#

!vcc1=1!vcc2=0!vcc3=1!rsn1#

!vcc1=1!vcc2=1!vcc3=0!rsn2#

!vcc1=0!vcc2=1!vcc3=1!rsn3#



1st line
: If input 1 is closed (!i1c), then the variable 1 attains the value 1 (!vmc1=1).


2nd line: If input 1 is open (!i1o), then the variable 1 attains the value 0 (!vmc1=0).


3rd line: If input 2 is closed (!i2c), then the variable 2 attains the value 1 (!vmc2=1).


4th line: If input 2 is open (!i2o), then the variable 2 attains the value 0 (!vmc2=0).


5th line: If input 3 is closed (!i3c), then the variable 3 attains the value 1 (!vmc3=1).


6th line: If input 3 is open (!i3o), then the variable 3 attains the value 0 (!vmc3=0).


7th line: If variable 1 gets the value 1 (!vcc1=1), the variable 2 the value 0 (!vcc2=0) and the variable 3 the value 1 (!vcc3=1), then the first show (001_SHOW.WM1) starts in normal mode (!rsn1).


8th line: If variable 1 and 2 gets the value 1 (!vcc1=1)(!vcc2=1) and the variable 3 the value 0 (!vcc3=0), then the second show (002_SHOW.WM1) starts in normal mode (!rsn2).


9th line: If variable 1 gets the value 0 (!vcc1=0), the variable 2 the value 1 (!vcc2=1) and the variable 3 the value 1 (!vcc3=1), then the third show (003_SHOW.WM1) starts in normal mode (!rsn3).