Each command line of the Control.ini must always start with the definition of a trigger event.

As a start condition either an "!i: Input event", "!t: Time event", "!rc: Real time clock event", "!v: Variable event", "!d: DMX event" or "!k: Infrared event" can be used.

 


Attention!

The limit is one trigger event per line (!i, !t, !rc, !v, !d or !k)!

Only variable conditions can be combined in one line. If you need a combination of several trigger events you have to do this via variables.



!i: Input event


Event related to the remote inputs 1-16.


A level change may be definded as "close" (activation of an input), "open" (deactivation of an input) or "toggle" (every level change of an input). With toggle, both the press and the release of a key action will cause a trigger event.


!i1c!...# -> If input 1 is actived (c=close), then the downstream command will be executed.


!i1o!...# -> If input 1 is deactived (o=open), then the downstream command will be executed.


!i1t!...# -> If input 1 changes (t=toggle), then the downstream command will be executed.